2. Rectifier/Regulator
|
CHECKING THE RECTIFIER/REGULATOR
1. Check:
• Charging voltage
If out of specification -> Replace the rectifier/ regulator.
1. Check:
• Charging voltage
If out of specification -> Replace the rectifier/ regulator.
a. Attach the engine tachometer to the spark plug lead of the front cylinder.
b. Connect the pocket tester (DC 20 V) to the battery terminals as shown.
b. Connect the pocket tester (DC 20 V) to the battery terminals as shown.
• Positive tester probe -> positive battery terminal "1"
• Negative tester probe -> negative battery terminal "2"
• Negative tester probe -> negative battery terminal "2"
c. Start the engine and operate it run at approximately 5,000 RPM/Min.
d. Measure the charging voltage.
d. Measure the charging voltage.
© 2013-15 cvvmax. No animals, HDs or Ducatis were harmed in the making of this site.